2SJ438(AISIN,Q,M)-VB Product details
Product introduction:
File download
Download PDF document
Download now
Product parameter:
| VB Package | Configuration | VDS(V) | VGS | Vthyp(V) | ID(A) | Rds2.5 | Rds4.5 | Rds10 | Technology |
|---|---|---|---|---|---|---|---|---|---|
| TO220F | Single-P | -60V | -1.7V | -20A | 120(mΩ) | 100(mΩ) | Trench |
| VB Package | Configuration | VCE | VGE | VGEth(V) | VCEsat15V | ICE | Technology |
|---|---|---|---|---|---|---|---|
| TO220F | Single-P | Trench |
| VB Package | Configuration | VDS(V) | VGS | Vthyp(V) | ID(A) | Rds18 | Technology |
|---|---|---|---|---|---|---|---|
| TO220F | Single-P | -60V | -1.7V | -20A | Trench |
| VB Package | Configuration | VDS(V) | VGS | Vthyp(V) | ID(A) | Rds6 | Technology |
|---|---|---|---|---|---|---|---|
| TO220F | Single-P | -60V | -1.7V | -20A | Trench |
| VB Package | Polarity | Vz / VR | Pd | VF | IF | IR | Cd | Type |
|---|---|---|---|---|---|---|---|---|
| TO220F | Single-P |
Gate-Source Voltage (VGS): ±20V
Threshold Voltage (Vth): -1.7V (Typical)
On-Resistance (VGS=4.5V): 120mΩ (Typical)
On-Resistance (VGS=10V): 100mΩ (Typical)
Maximum Drain Current (ID): -20A
Package: TO220F
Technology: Trench
Domain and module applications:
Application Areas and Modules
1. Power Inversion and Negative Voltage Conversion: Used in DC-AC inverters, negative voltage buck-boost circuits, utilizing low on-resistance to reduce losses and improve power conversion efficiency.
2. Battery Discharge Management: Acts as a high-side or low-side discharge main switch, works with protection IC to achieve fast overcurrent and overvoltage shutdown, suitable for power tools and energy storage equipment.
3. Motor Drive Control: Drives medium and low power DC brushless or brushed motors, suitable for fans, pumps, electric valves, and industrial actuators, supports PWM speed control.
4. Automotive Electronic Systems: Provides reverse protection and power switching for loads such as lighting, instruments, and sensors in 12V/24V vehicle networks.
5. Power Adapter and Charger: Used for synchronous rectification auxiliary switches or load switches, reducing rectification losses, suitable for medium and high power adapter designs.
6. Industrial Control Unit: Integrated into PLCs, inverters, and servo drive auxiliary circuits, achieving reliable power path management and signal isolation.
7. Load Switch and Power Distribution System: Used in smart power distribution units, UPS, and communication base stations, achieving negative voltage side load on/off and power distribution.
Technical support:
* If you have any questions about the product, please fill out the form to submit, we will reply you within 24 hours