graph LR
subgraph "三相整流與PFC"
A[三相380VAC] --> B[EMI濾波器]
B --> C[三相整流橋]
C --> D[PFC升壓電路]
D --> E[高壓直流母線 \n 400-540VDC]
end
subgraph "LLC諧振變換器"
E --> F[LLC諧振網路 \n Lr, Cr, Lm]
F --> G[高頻變壓器 \n 初級繞組]
G --> H[LLC開關節點]
subgraph "高壓半橋開關"
Q1["VBP15R11S \n 500V/11A"]
Q2["VBP15R11S \n 500V/11A"]
end
H --> Q1
H --> Q2
Q1 --> I[初級地]
Q2 --> I
J[LLC控制器] --> K[隔離柵極驅動器]
K --> Q1
K --> Q2
G -->|電壓回饋| J
end
subgraph "次級高壓生成"
L[變壓器次級] --> M[高壓倍壓整流]
M --> N[高壓濾波網路]
N --> O[X射線管高壓輸出 \n 30-150kV]
end
subgraph "保護電路"
P[RCD緩衝網路] --> Q1
Q[RC吸收電路] --> Q2
R[TVS保護] --> K
end
style Q1 fill:#e8f5e8,stroke:#4caf50,stroke-width:2px
style Q2 fill:#e8f5e8,stroke:#4caf50,stroke-width:2px
低壓大電流同步整流拓撲詳圖
graph TB
subgraph "同步Buck變換器"
A[高壓直流母線 \n 400-540VDC] --> B[輸入電容陣列]
B --> C[開關節點]
subgraph "同步開關對"
Q_H["VBE1105 \n 100V/100A"]
Q_L["VBE1105 \n 100V/100A"]
end
C --> Q_H
C --> Q_L
Q_H --> D[中間匯流排 \n 12V/24VDC]
Q_L --> E[功率地]
F[同步Buck控制器] --> G[柵極驅動器]
G --> Q_H
G --> Q_L
D -->|電壓回饋| F
H[電流檢測] -->|電流回饋| F
end
subgraph "輸出濾波與分配"
D --> I[輸出濾波電感]
I --> J[輸出電容陣列]
J --> K[12V匯流排]
J --> L[24V匯流排]
K --> M[數字電路供電]
K --> N[模擬電路供電]
L --> O[電機負載供電]
L --> P[通信介面供電]
end
subgraph "保護與監測"
Q[過流保護電路] --> Q_H
Q --> Q_L
R[溫度感測器] --> S[熱管理MCU]
T[輸入TVS] --> B
U[輸出TVS] --> J
end
style Q_H fill:#e3f2fd,stroke:#2196f3,stroke-width:2px
style Q_L fill:#e3f2fd,stroke:#2196f3,stroke-width:2px
智能負載管理與熱控制拓撲詳圖
graph LR
subgraph "雙路智能負載開關(VBA4309)"
A[MCU控制信號] --> B[電平轉換電路]
B --> C["VBA4309 Channel 1"]
B --> D["VBA4309 Channel 2"]
E[12V/24V輔助電源] --> C
E --> D
C --> F[冷卻水泵]
D --> G[散熱風扇]
F --> H[電源地]
G --> H
end
subgraph "溫度監測與PWM控制"
I[溫度感測器1 \n X射線管溫度] --> J[熱管理控制器]
K[溫度感測器2 \n MOSFET溫度] --> J
L[溫度感測器3 \n 環境溫度] --> J
J --> M[PWM信號發生器]
M --> N[冷卻泵PWM]
M --> O[風扇PWM]
N --> F
O --> G
end
subgraph "故障保護與診斷"
P[電流檢測電路] --> Q[過流比較器]
R[電壓檢測電路] --> S[欠壓/過壓保護]
Q --> T[故障鎖存器]
S --> T
T --> U[關斷信號]
U --> C
U --> D
T --> V[故障指示燈]
T --> W[故障記錄]
end
subgraph "燈絲預熱控制"
X[MCU] --> Y["VBA4309 \n 燈絲控制"]
Z[輔助電源] --> Y
Y --> AA[X射線管燈絲]
AA --> AB[燈絲地]
end
style C fill:#fff3e0,stroke:#ff9800,stroke-width:2px
style D fill:#fff3e0,stroke:#ff9800,stroke-width:2px
style Y fill:#fff3e0,stroke:#ff9800,stroke-width:2px
熱管理與保護電路拓撲詳圖
graph TB
subgraph "三級散熱系統架構"
subgraph "一級: 液冷/水冷系統"
A[冷卻液儲罐] --> B[迴圈泵]
B --> C[冷板1: 高壓MOSFET]
C --> D[冷板2: X射線管]
D --> E[散熱器]
E --> F[冷卻風扇]
F --> A
end
subgraph "二級: 強制風冷系統"
G[進氣口] --> H[空氣篩檢程式]
H --> I[風道散熱器 \n 低壓MOSFET]
I --> J[排氣口]
K[系統風扇] --> I
end
subgraph "三級: PCB熱設計"
L[多層PCB] --> M[大面積敷銅層]
N[導熱過孔陣列] --> O[散熱焊盤]
P[散熱片] --> Q[控制IC與負載開關]
end
end
subgraph "溫度監測網絡"
R["NTC感測器1 \n (高壓MOSFET)"] --> S[溫度採集電路]
T["PT100感測器2 \n (X射線管)"] --> S
U["數字感測器3 \n (環境溫度)"] --> S
S --> V[熱管理MCU]
V --> W[PWM控制輸出]
W --> X[泵速調節]
W --> Y[風扇調速]
W --> Z[負載降額控制]
end
subgraph "電氣保護網路"
AA[RCD緩衝電路] --> AB[高壓開關管]
AC[RC吸收電路] --> AD[諧振電容]
AE[TVS陣列] --> AF[柵極驅動晶片]
AG[肖特基二極體] --> AH[同步整流管]
AI[電流互感器] --> AJ[比較器電路]
AK[電壓分壓器] --> AL[ADC監測]
AJ --> AM[故障鎖存器]
AL --> AM
AM --> AN[系統關斷信號]
AN --> AB
AN --> AH
end
style AB fill:#e8f5e8,stroke:#4caf50,stroke-width:2px
style AH fill:#e3f2fd,stroke:#2196f3,stroke-width:2px
style Q fill:#fff3e0,stroke:#ff9800,stroke-width:2px
*To request free samples, please complete and submit the following information. Our team will review your application within 24 hours and arrange shipment upon approval. Thank you!
X
SN Check
***Serial Number Lookup Prompt**
1. Enter the complete serial number, including all letters and numbers.
2. Click Submit to proceed with verification.
The system will verify the validity of the serial number and its corresponding product information to help you confirm its authenticity.
If you notice any inconsistencies or have any questions, please immediately contact our customer service team. You can also call 400-655-8788 for manual verification to ensure that the product you purchased is authentic.